This page was exported from Free Exam Dumps Collection [ http://free.examcollectionpass.com ] Export date:Wed Nov 27 22:39:28 2024 / +0000 GMT ___________________________________________________ Title: Get Instant Access of 100% Real Huawei H12-425_V2.0-ENU Exam Questions with Verified Answers [Q62-Q77] --------------------------------------------------- Get Instant Access of 100% Real Huawei H12-425_V2.0-ENU Exam Questions with Verified Answers Exam Dumps for the Preparation of Latest H12-425_V2.0-ENU Exam Questions NO.62 The parameter display of the PDU8000 smart power meter is abnormal, which may be due to? (Multiple choice)  The current or voltage change is set incorrectly  The corresponding voltage acquisition circuit is abnormal  Corresponding current transformer fault  Smart power meter failure NO.63 ECC800 supports two AC inputs.  True  False NO.64 What are the steps to maintain the electrode humidifier when the NETCOL5000-A removes the air conditioner humidifier? (Multiple choice)  Disconnect the water supply valve drain valve wiring  Remove the drain and drain valve assembly  Remove and clean the water supply valve  Replace hard and brittle hoses and flush drains thoroughly NO.65 Unpredictable business, difficult expansion and investment are one of the challenges faced by traditional data center business development.  TRUE  FALSE NO.66 The UPS5000-E power chess block adopts a fan fault-tolerant design. When two of the fans are damaged, what percentage of the power module can still be loaded?  0.3  0.5  0.2  0.6 NO.67 Cold/hot aisle containment is an energy-saving technology used to solve cooling problems in data centers.  True  False NO.68 When UPS5000-E shares a battery pack, the battery capacity parameter of each UPS is set to the total capacity of the entire battery pack.  TRUE  FALSE NO.69 Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack is 1+1 redundant, the single-machine backup power scheme is adopted, the backup power scheme for each machine, 3 sets of batteries per rack, 40 cells per set, the capacity of the main switch box is:  630A  500A  250A  320A NO.70 Which is not part of the routine maintenance item of the ECC800 power module?  Check if the power indicator light is normal  Check the ECC800 module fan  Check whether the power wiring is loose  Create a micromodule plan view NO.71 The AI/DI port on the access control actuator supports to connect the ().  IC card reader  Fingerprint Reader  Door open button  Electronic magnetic lock NO.72 What is the channel type of a typical configuration of FusionModule800? Is a cold aisle or a hot aisle?  Cold Aisle  Hot Aisle NO.73 A single row of FusionModule2000 supports a maximum of ( ) cabinets. (Fill in the blank)  24 NO.74 When the NetCol5000-A compressor runs for a long time with low superheat or no superheat, it is prone to “liquid shock” and damage.  True  False NO.75 What is the maximum capacity of the power module of the UPS5000-E?  30kVA  20kVA  50kVA  40kVA NO.76 FusionModule500&FusionModule800 display brand optional ()?  Blu-ray  Huawei Honor  apple  Samsung NO.77 The power supply structure adopted by the new line-level half-cabinet chilled water is:  Single power supply  Dual power supply  Both A and B are right  Other  Loading … Download Latest & Valid Questions For Huawei H12-425_V2.0-ENU exam: https://www.examcollectionpass.com/Huawei/H12-425_V2.0-ENU-practice-exam-dumps.html --------------------------------------------------- Images: https://free.examcollectionpass.com/wp-content/plugins/watu/loading.gif https://free.examcollectionpass.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-04-24 09:23:29 Post date GMT: 2023-04-24 09:23:29 Post modified date: 2023-04-24 09:23:29 Post modified date GMT: 2023-04-24 09:23:29